Author / organization: Oliver Gehrke / DTU
Used component model implementation: NHN Battery
Columns description:
- Name: SOC
Description: state of charge of the entire battery
Unit: %
Min-value / max-value: 0 / 100
- Name: P_set
Description: requested discharge rate (negative values=battery is requested to charge) of the entire unit, measured at AC terminals
Unit: kW
Min-value / max-value: -200 / 200
- Name: P_max_chg
Description: maximum charge rate allowed by BMS at current operating point
Unit: kW
Min-value / max-value: -200 / 200
- Name: P_max_dis
Description: maximum discharge rate allowed by BMS at current operating point
Unit: kW
Min-value / max-value: -200 / 200
- Name: P_inst
Description: instantaneous power production/discharge (negative values=power consumption/charge) of the entire unit, measured at AC terminals
Unit: kW
Min-value / max-value: -200 / 200
- Name: Q_set
Description: requested reactive power production (negative values=requested consumption) of the entire unit, measured at AC terminals
Unit: kW
Min-value / max-value: -200 / 200
- Name: P_set
Description: instantaneous reactive power production (negative values=power consumption) of the entire unit, measured at AC terminals
Unit: kW
Min-value / max-value: -200 / 200
- Name: rem_cap
Description: remaining capacity of the battery unit, i.e. rated capacity minus ageing
Unit: kWh
Min-value / max-value: 0 / 22
- Name: inst_age
Description: instantaneous cycle age of the battery, in full cycle equivalents
Unit: cycles
Min-value / max-value: 0 / 10000