Breadcrumb

Asset Publisher

Content with Scope Ancillary Service times .

Joint UC3: Heat for Electricity - details

Use Case Details Description of the use case Joint UC4 Intersection of consortium partners DTU, AIT, KIT Intersection with partner...

KIT.TC1.TS1 FlexOffice Thermal MPC test system model implemntation - evaluation

Evaluation of System State and Test Signal Figure E.5 shows typical open-loop trajectories for the given disturbances and fixed input from D4.1. Figure E.6 shows typical closed-loop...

KIT.TC1.TS1 FlexOffice Thermal MPC test system model implemntation - overview

Test System Model Implementation Overview Author / organization: Alexander Engelmann / KIT Implemented Component Models / Implementation Tool: Electrical distribution grid ...

KIT.TC1.TS1 FlexOffice Thermal MPC test system model implemntation - short description

Short Description In this test aims at evaluating the capabilities of a MPC to optimize the system behaviour with respect to the previously defines KPIs and the OF. Specifically, this is...

NHN.TC1.TS1 - description

Short Description The aim of this test system is to characterizing service provision by power-to-heat units through supervisory controllers. This test characterizes district operation with...

NHN.TC1.TS1 test system model implementation - overview

Test System Model Implementation Overview Author / organization: Tue Vissing Jensen / DTU Implemented Component Models / Implementation Tool: Electrical distribution grid ...

NHN.TC1.TS1 test system model implementation - short description

Short Description This test system model seeks to characterize the impact use of local flexibility has on available regulating power from a local district. The characterization concerns the...

Simulation Results of KIT.TC1.TS1 FlexOffice Thermal MPC - long description

Results Description of Simulation -- KIT.TC1.TS1 FlexOffice Thermal MPC   Figure 3 shows an open-loop optimal trajectory, which is the solution of OCP for one time instant with...

Simulation Results of KIT.TC1.TS1 FlexOffice Thermal MPC - short description

Short Description of simulation Results We have to distinguish two types of results here: In each time step, we get an open-loop optimal trajectory which is the solution to OCP solved at...

Simulation Results of KIT.TC1.TS1 FlexOffice Thermal MPC - setup

Simulation Setup & Configurations Author / organization: A. Engelmann and T. Faulwasser / KIT Objective Function of Simulation: Weighted sum of KPIs (Comfort Level, Fluctuation...

SizingHPandStorageToMaximizeSelfConsumption test system model implementation - overview

Test System Model Implementation Overview Author / organization: Sami Ghazouani and Mickael Rousset / EDF Implemented Component Models / Implementation Tool: HeatPump...

Use Case UC 11 - description

Short Description The occupants of the rooms have to agree on temperature limits of the building, such that they can be used as heat storages. One possible control scheme would be Model...

Use Case UC 11 - details

Use Case Details Description of the use case UC11 ID UC11 System configuration(s) SC Office Buildings 445 and 449 at KIT...

Use Case UC 11 - overview

Use Case Overview Author / organization: A. Engelmann Date: 05/07/2017 Version No.: 1.0 Belongs to use case group (if applicable): Building Energy Management

Use Case: VITO/Automated demand response for intraday RE balancing

Description Of The Use Case Name of use case Use case identification ID System configuration(s) ...
— 20 Items per Page
Showing 15 results.