THERMAL ENERGY STORAGE Implementation
ThermalEnergyStorage Component Model Implementation - title
ThermalEnergyStorage Component Model Implementation
ThermalEnergyStorage Component Model implementation - overview
ThermalEnergyStorage Component Model Implementation - Overview
Author / organization: Benedikt Leitner / AIT
Used Compoent model specification: Thermal Energy Storage Specification
Model of computation:
- Time-continuout
Simulation description: the electric heater is connected to a cold source (30°C) and receives mass flow setpoints. These setpoints start at zero and rise above the nominal mass flow of the component to show its behaviour at both design and off-design situations.
Implementation tool:
- Dymola and MATLAB/Simulink
- AnyLogic or MATLAB/SimEvents
Battery KIT - Related Documents
ThermalEnergyStorage Component Model implementation - short description
Short Description
A model of a stratified storage tank for thermal energy storage.
Present use / development status
The model is part of AIT’s internal Modelica library for district heating and is usable for co-simulation with electric network models. The Modelica library uses the Modelica standard library and the IBPSA library as a core.
ThermalEnergyStorage Component Model implementation - related documents
Source Code of the Implemented Result Object
Please contact:
Name: Benedikt Leitner / AIT